Philips CD-i Timekeeper Clock Calibration

If your CD-i player’s clock is way off, then you can try to make use of the Timekeeper clock calibration tool of the low-level test. Be aware that it needs an accurate frequency counter and won’t help if your Timekeeper suffers from an empty battery.

Here are some NVRAM+RTC solutions. The 8 KB chips operate within the accuracy of ± 1,53 minutes per month at 25 °C (and the 32 KB socket better than ± 1 minute per month).
8 KB – ST MK48T08B and M48T08 Timerkeeper.
8 KB – Dallas/Maxim DS1643 NV Timekeeping RAM.
32 KB – Dallas/Maxim DS1216C SmartWatch RAM (with Mitsubishi M5M5256DP SRAM).

Philips CD-i 8 and 32 KB NVRAM
Philips CD-i 8 and 32 KB NVRAM
Continue reading Philips CD-i Timekeeper Clock Calibration

Philips CDI470 32 KB NVRAM Upgrade

Some time ago, I noticed that the service manuals of most Mono II – IV boards have notes about 8 and 32 KB NVRAM types, to be set by jumpers and resistors. I never attempted to do that upgrade because most of my CD-i players feature 32 KB NVRAM or have older mainboards that cannot be upgraded. When I mentioned the possibility in this article, CD-i Fan warned me about the consequences: If device driver and descriptor in the ROM don’t support the extra RAM, then the player might not recognize it and lose the real-time clock – or it won’t work at all.

Why would you want to upgrade the NVRAM anyways?
For example, the save files of The 7th Guest, Lost Eden and Burn:Cycle already take up a lot of space. Add some more games and settings, and you will soon reach the critical limit of 97-98% where the player refuses to start.

CD-i memory full (8 KB)
CD-i memory full (8 KB)
Continue reading Philips CDI470 32 KB NVRAM Upgrade

Philips CDI470 Diagnosis and Repair

For upcoming experiments, I was in need of a working CD-i player with a Mono IV mainboard and 8 KB of NVRAM. I checked my basement and found a broken CDI470/20 that had been sitting there for years. Previous repair attempts had failed and I hadn’t bothered to look at it since.

Upon the first start, it greeted me with the memory full error:

CD-i memory full error
CD-i memory full error
Continue reading Philips CDI470 Diagnosis and Repair

Serial Terminal on Psion Serie 5mx Pro

This is a follow-up to the Serial Terminal on Atari Portfolio article. The Portfolio with the Serial Interface add-on turned out to be too limited and bulky for being a mobile VT100 terminal, and I actually never used it. For years, I was looking for an even smaller alternative and have finally found it: The Psion Serie 5mx Pro. It is basically a Psion Series 5mx (or Ericsson MC218) for the German market. The operating system (EPOC32 Release 5) of this model is not stored in ROM, but instead it is loaded from the CF card into RAM on the first start. An English version of the operating system file (sys$rom.bin) can be found here.

Psion Serie 5mx Pro and Philips CDI470
Psion Serie 5mx Pro and Philips CDI470
Continue reading Serial Terminal on Psion Serie 5mx Pro

Philips CDI660 Mono IV NVRAM and 60 Hz Modification

The CDI660/00 is one of the last professional CD-i players by Philips. The mainboard, Mono IV, is also used in various consumer players. So far, there are no tutorials for 60 Hz modification. When this topic came up in the community on The world of CD-i, I looked it up in the CDI220/80 service manual (also Mono IV, with plenty of remarks for other player models) and attempted the modification myself. It has been on my to-do list for quite some years now.
First, we need full access to mainboard. Remove the marked screw of the DVC plastic holder.

CDI660 inside
CDI660 inside
Continue reading Philips CDI660 Mono IV NVRAM and 60 Hz Modification

Philips CDI605T Disassembly and Repair

My Philips CDI605T/20 needed repairs before I can fully use it. Some of them was mandatory for operation (Timekeeper), some of them to make it easier on the ears (fan, optical disc drive tray). I already had experience with a Mini MMC chassis on the very similar consumer player CDI220/00 and knew what awaited me inside (its service manual helped a bit). It is actually possible to perform these repairs without taking the entire case apart (see shortcuts). I took special precautions and made photos of each and every step to be able to put everything back together in the end.

I began with removing the case and the bezels of the extension cards on the rear. Make sure to slide out the lower card first, otherwise its metal plate will grind on the solder side of the upper card.

Philips CDI605T extension cards 22ER9132 (Ethernet, SCSI, 4 MB RAM) and 22ER9424 (DVC R2.1, 1 MB RAM)
Philips CDI605T extension cards 22ER9132 (Ethernet, SCSI, 4 MB RAM) and 22ER9424 (DVC R2.1, 1 MB RAM)
Continue reading Philips CDI605T Disassembly and Repair

First Steps in OS-9 on Philips CDI605T

The Philips CDI605T/20 is the last professional CD-i player with authoring / development capabilities. As every other CD-i player, it runs on CD-RTOS v1.1, a real-time operating system based on Microware OS-9/68K v2.4. Additionally, it features extended memory, an internal OS-9 shell, a floppy disk drive, SCSI, ethernet, RS-232C and printer ports. When compared to its predecessor CDI605/00, it was upgraded with a tray loading mechanism, a built-in DVC and a newer system ROM v1.3. Even though this player is perfectly fine for playing the whole range of consumer CD-i titles, I got it mainly for experimenting with the titles and the operating system. On the first start, it performed a CRC check and displayed the software version:

CDI605T CRC check
CDI605T CRC check
Continue reading First Steps in OS-9 on Philips CDI605T

TAB Quizard on Philips CD-i

Quizard was a series of quiz games published by TAB-Austria in the ’90s. What makes it special is the fact that it is one of the very few arcade games based on Philips CD-i hardware. The protection of Quizard 1.x and 2.x has been figured out quite a while ago and since then it is emulated in MAME. Quizard 3.x and 4.x, however, refused to run – until now. A first step was done when Team Europe dumped a protection MCU a couple of years ago. Very soon, they will release an MCU board that will turn almost every CD-i player into a Quizard arcade machine. I received a sample last week and just finished assembling and testing it.

Continue reading TAB Quizard on Philips CD-i

IBM ThinkPad 760 Series MIDI/Game Port Adapter

While doing my research for another project (finding a plug for the Philips CDI350 RGB in/out port), I came across an old IBM MIDI/Game port adapter. It is listed with P/N 29H9467 (FRU P/N 29H9269) and can be used with some models of the ThinkPad 760 series (760CD, 760ED, 760XD, and also 765D). What makes it so special is the plug. It is similar to the 26-pin external floppy connectors used by several laptop brands in the ’90s. While most of the external floppy drives used a 17 mm wide plug, this one is 20 mm wide. This JAE datasheet lists the plug as TX20A series connector, part number TX20A-26PH1-D2P1-D1.

Continue reading IBM ThinkPad 760 Series MIDI/Game Port Adapter

Philips CDI350 Repair Part 2

Last year I began to disassemble and repair one of my Philips CDI350 players. This has been covered in the article Philips CDI350 Repair Part 1.

After that, it took me a while to make a list of all capacitors, to find replacement parts (the original Philips part numbers are not useful anymore) and to find shops that had them on stock.

The scanned CDI350 service manual on ICDIA is missing the pages 78 and 79, which contain the parts lists of the servo and power sections. I found some of the missing parts in the CDI360 service manual and some by comparing the removed parts with both service manuals.

Continue reading Philips CDI350 Repair Part 2